How to address the connection forms and malfunctions of electric valves
电动阀门连接的形式有很多种,一般常见的阀门连接方式有:法兰连接、对夹连接、对焊连接、螺纹连接、卡套连接、卡箍连接、自密封连接等连接形式。
接下来将着重对常见的法兰连接、对焊连接和螺纹连接在安装过程中容易出现的问题进行解说,希望对大家有所帮助。
电动阀门出现故障如何解决?在维修时的注意点,有以下几条:
1、检查各联接部位要求压紧,即保障填料的密封性,又可保障阀杆转动灵活。
2、金属密封电动阀门不适合安装于管路末端,如须安装于管路末端,需采取配装出口法兰,制止密封圈积压、过位。
3、阀杆安装使用反应定期检查阀门使用成效,发现故障及时检修。
4、电动阀门安装在管道中的位置,较好的位置为立装,但不能倒装。
5、电动阀门使用中需要调节流量,有气动执行机构进行控制。
6、开、闭次数较多的手动蝶阀,在二个月左右时间,打开蜗轮箱盖,检查黄油是否正常,应保持适量的黄油。
电动阀门的应用范围越来越广,对于在不同的环境下应使用相对应的阀门。而整个阀门在与管路或设备之间的连接各有不同。不管是安装或是使用和维护都是需要注意的,阀门连接方式的不适当,容易发生阀门的跑、冒、滴、漏等现象。因此阀门使用者要根据具休情况具体对待。
There are many types of connections for electric valves. Common valve connection methods include flange connection, wafer connection, butt welding connection, threaded connection, ferrule connection, clamp connection, self-sealing connection, and other connection types.
Next, we will focus on explaining the common issues that may arise during the installation of flange connections, butt welding connections, and threaded connections. We hope this will be helpful to everyone.
How to solve the problem of electric valve malfunction? There are several points to note during maintenance:
1. Check that all connecting parts are tightly pressed, ensuring both the sealing performance of the packing and the flexibility of the valve stem rotation.
2. Metal-sealed electric valves are not suitable for installation at the end of pipelines. If they must be installed at the end of pipelines, it is necessary to equip them with outlet flanges to prevent the sealing rings from being compressed or misaligned.
3. Regularly inspect the valve's performance during valve rod installation and use, and promptly repair any malfunctions found.
4. The preferred position for installing an electric valve in a pipeline is in an upright position, but it should not be installed upside down.
5. When using electric valves, it is necessary to adjust the flow rate, which is controlled by a pneumatic actuator.
For manual butterfly valves that are opened and closed frequently, after about two months, open the worm gear box cover to check if the grease is normal. A proper amount of grease should be maintained.
The application scope of electric valves is becoming increasingly wide, and corresponding valves should be used in different environments. The connections between the entire valve and the pipeline or equipment vary. Whether it is installation, use, or maintenance, attention must be paid. Improper valve connection methods are prone to phenomena such as valve leakage, emission, dripping, and leakage. Therefore, valve users should treat specific situations accordingly.